 1 DC brushless speed regulating motor: the real ideal speed regulating motor, fast speed, high precision, very low heat, starting torque, small starting current, good speed regulating performance

2 Mechanical transmission: using planetary gear structure, transmission efficiency of 95%, strong bearing capacity / impact resistance, conducive to speed regulation and torsion increase

Control circuit: simple control unit, good stability, and few fault points

3 Super strong overall luxury shape design, independent functional unit structure, double seal protection

4 Speed adjustment, high precision

5 Speed / torque can be set online

Category: G / S Series-DC Speed (versatile)
Share:
  • Description
  • CONTACT
Description

Product Presentation:


1. non-free cover non-immersion design: no need to open the cover, through the magnetic button on the operation panel or infrared remote control can be parameter set, control, browse;

2. rich display functions: valve position, sensor position, input and output, all kinds of alarms, faults, all menus are displayed in Chinese / English text, instead of symbols, code display;

3. mechanical transmission: using the differential planetary gear transmission principle, efficiency, bearing capacity, high impact capacity is huge, mechanical life is far greater than the worm wheel worm or positive gear structure;

4. the motor speed is adjustable: the real sense of DC speed adjustment, flexible slow opening, flexible slow closing, any stroke section arbitrary set speed, play a good role in protecting the valve;

5. Adjustable torque: the field torque, thrust and overload protection value can be reset for the running actuator (see the commissioning manual for FF2);

6. Important to avoid water hammer and gas erosion: the full stroke can be divided into three stages (valve opening stage, intermediate process and valve closing stage), and the torque, speed and time requirements of each stroke can be set arbitrarily; the actuator can follow the valve flow characteristic curve;

7. electronic travel limit: advanced, high precision electronic travel limit, when setting the stroke, only click or hand wheel to move the valve to the full close or full open position, press the “confirm” key to complete the travel limit, very convenient;

8. strong interference crash automatic recovery function: when the powerful and complex signal interference to the actuator crash, the control system quickly make a judgment, no more than 20ms automatically restore to the running state before the crash;

9. No clutch handwheel mechanism: Due to the planetary gear transmission principle, no clutch mechanical design rotates the handwheel without causing damage to the actuator; even under the remote control state, the manual forced transfer handwheel, once the handwheel is released, the actuator automatically returns to the last command position;

10. Local / remote worry-free switch: click the button on the operation panel or infrared remote control to complete the switch;

11. protection function: broken signal, transition, over temperature, missing items, lost items, sensor position, over torque, operation reverse, and other output alarm, and real-time display, record:

12. Start the self-test function: fault self-diagnosis display alarm:

13. Level 2 overtorque protection value, F1 overtorque protection is designed to ensure that the torque is monitored; when F1 is insufficient to drive the valve, the actuator sends alarm, but can continue to work, automatically jump to F2 protection value (F1 F2); when F2 alarm, the actuator stops working to prove that the torque selection is seriously small, please contact the supplier;

14. the card plugging function: when the valve encountered card / blocking phenomenon, the system will automatically try to impact three times, the card / blocking phenomenon is removed, automatic operation, the card / blocking is not successful, start the alarm;

15. start frequency: DC brushless many advantages and electronic reversing technology, decided that the actuator can be reversing operation in any state, will not cause damage to the motor;

16. PID control: the stop start / stop of DC brushless motor is compared by PID according to the position and speed of the CPU at 16000 operation speed per second, the speed is reduced to 0 before reaching the position, no overshoot, valve position high precision control, and no drift;

17. Adopt electronic switching technology, not limited by the startup frequency:

18. Modular design: independent mechanical transmission unit, motor unit, control unit, display unit, terminal connection unit;

19. ESD: ESD function, whether locked with SIS or controlled by DCS, always automatically execute the preset state process;

20. split installation: for high temperature, narrow space, strong vibration conditions suggest split installation;

21. field bus: standardized mA, switch volume signal control, modular plug and pull type add bus control unit;

22. Support the Internet of Things, APP, CS-wireless remotte control wireless remote control;

23. Solar energy: support solar power supply and wireless signal transmission functions in areas that provide mains power;

24. Energy saving and environmental protection: DC motor energy saving effect is incomparable, up to 40-50%.

Product Parameter:


parameter of electric motor:

Motor Type Permanent magnet DC brushless speed-regulating motor Motor structure special designing Motor material 63M-160L aluminum alloy Mower of motor 30/60/90/375/800/1500W
Motor speed 4000rpm (4000~10000rpm) Speed adjustable range 15%~100% Torque adjustable range 10~100% Temperature protection 130℃
The motor direction electronic commutation Motor direction interval immediately The Motor overflush 0.25rpm Motor load rate (t / h) Switch type S2,100%, maximum of 60 min
Motor load rate (t / h) Regulatory S4,100%, maximum 3600 times Transport inertia 20g.cm2 Cooling-down method Air cooling naturally Insulation grade H level

 

Standard configuration of the technical parameters:

Power supply 24/36/48/72VDC 110/230/400VAC±25% 50/60Hz Torque / thrust 100~56000Nm 2~120KN Speed adjustable range 15~100% Torque adjustable range 10~200%
Torque detection electronic formula Torque detection accuracy ±3% LCD liquid-crystal display Single page 4 lines, can be viewed through the screen Position sensor 1 / 4096 Absolute value position encoder
import Simulation quantity: 0 / 4-20 mA switching value No-Off output Simulation quantity: 0 / 4-20 mA switching value Passive dry contact point wet contact point
positioning accuracy ±0.1-0.3% response time of receive the command 50ms Ambient temperature -20~85℃ or -40~60℃ ambient humidity 100%RH
levels of protection IP68 (normal use within 12m underwater, special instructions for ordering) anti-hazard classification Ex dII CT5 defencive function complete Configuration alarm output six
infrared remote control support Split installation Split control box: LCD display, operation button, control unit, etc., is placed at 10m (special instructions for 10m or 40m when ordering) communication ProFiBUS-DP ModBUS HART SCDAD antiknock characteristics Manufacturer’s test standard: 600Hz 3 axis direction 10g for 180 days without failure
CONTACT

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

You have a requirement, we have holistic solutions. Let’s talk!

Our enthusiastic and professional customer service team is ready to listen to your needs and explore tailored solutions to enhance your business efficiency. Contact us now to begin your exclusive consultation service!

Contact Us

Products

  • All products
  • DAUME Valve
    • Ball Valve
    • Butterfly Valve
    • Control Valve
    • Emergency Shut Valve
    • Gate Vavle
    • Regulating Valve
  • Vertical double power supply emergency shut-off electric control device
  • Electric Actuators
    • F/E Series-Common communication (economical)
    • G / S Series-DC Speed (versatile)
    • HW Series-General AC (Lotype)
    • MT Series-DC Speed Governor (Multiple Turns)
    • MTb Series-General AC (multiple turn)

Contact us

  • Company Address: Shanghai fengxian district is looking at the green space of the green space in 1518 south road
  • Factory Address: University of Technology, Zhongyuan Institute of Technology, Longhu Town, Zhengzhou City, Henan Province, China
  • Tel:+86 21 5230 2721
  • E-Mail: info@daume.com.cn

© 2024 Daume(shanghai)Control Technology Co.,Ltd
All Rights Reserve

  • HOME
  • About us
  • Products
  • Industrial Applications
  • Service and Support
  • News
  • CONTACT US
Start typing to see products you are looking for.

Contact us

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

*We respect your confidentiality and all information are protected.

Contact us

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

*We respect your confidentiality and all information are protected.